Electrician Training Electrical Certification wiring recessed light fixtures Electrical Wiring Electrical Troubleshooting and Electrical Repairs wire outdoor light fixture Home Electrical Wiring Diagrams

wiring home generator and transfer switch wiring a 220 volt range cord outlet Wiring for GFCI Outlets Wiring Outlets and a Switched Outlet Wiring and Installing Ceiling Fans and Remote Controls wire dimmer switch wiring diagrams for switches wiring a dryer cord and 220 outlet circuit breaker panel
Electrical Wire and Cable
ask the electrician
Electrician Training Electrical Certification wiring recessed light fixtures Electrical Wiring Electrical Troubleshooting and Electrical Repairs wire outdoor light fixture Home Electrical Wiring Diagrams
wiring home generator and transfer switch wiring a 220 volt range cord outlet Wiring for GFCI Outlets Wiring Outlets and a Switched Outlet How to Installing and Wire Ceiling Fans and Remote Controls wire dimmer switch wiring diagrams for switches wiring a dryer cord and 220 outlet circuit breaker panel
Electrical Wire and Cable

Garage rewiring project


home electrical rewiring By
Summary: Electrical Rewiring Question: I have been attempting to rewire parts of my garage, so I could have drywall hung. The box in the picture contains 4 wires.


Check Out What Others Are Sharing at Ask the Electrician:
Great web site! Thanks for all your help.Phillip from Friendswood, Texas

Electrical Rewiring: Garage rewiring project



Electrical Wiring Video

How to Wire a GFCI Outlet without a Ground Wire

NOTE: A List of All my Helpful Videos

Will Display at the End of This Video

So Keep Watching So I Can Help You Wire it Right!


Check out my YouTube Channel:
» AskTheElectrician «
and Subscribe!



Electrical Rewiring Question:
I have been attempting to rewire parts of my garage, so I could have drywall hung.

The box in the picture contains 4 wires. The two wires on the left appear to come from inside the house. The two wires on the right run to outlets and one of those continues on to another outlet.

When I originally opened this box, actually I replaced the box with a new one anyway, There was five wires running into the box and a light fixture attached to it. I have since removed one of the wires, it was attached to a switch on the wall. I also decided to not add a new light fixture back onto this box to try to limit the number of wires running into it.

Of the remaining four wires, one outlet work and one does not. Also an additional outlet in the garage and two outlets in the bathroom no longer work. When I originally opened this box, the outlet that is no longer working was attached to the light fixture. And one additional white wire was attached to the light fixture and just twisted in among the other white wires.

There was also one black wire twisted in with the white wires. It was my understanding that white go to white and black to black and grounds to grounds. Which is what I did. However, now I have outlets that don't work. So, I'm assuming that one black wire should be with the white wires. How do I determine which black wire goes with the white wires or is there another problem?

Do I need to attach a light fixture or outlet or something back up to this mess.

Any help would be greatly appreciated.
Thanks- Theresa B.

Hi Theresa, Great Questions and thanks for the picture Lets try and figure this out for you.

First, I need to say that typically when it comes to receptacles in the garage and in the bathroom, there should be GFCI - Ground Fault protection somewhere. This could be a GFCI Circuit Breaker at the panel serving this circuit or, there could be one or more GFCI receptacles, one possibly in a bathroom, one possibly in the garage - these are required by code. If you do not have GFCI protection anywhere, we can talk about options to provide that protection. If you do have GFCI protection, check the device and see if it was tripped. This could restore power to the plugs that are not working.

The GFCI receptacles can trip very easily. As for the original light switch, this is probably why you saw a white wire connected to one or more black wires. This scenario is used to run the switch legs ; power would travel to the switch through one wire, and the other would pass the current back to the light when the switch is operated.

If there are no other switches involved with these 4 lines coming into the junction box, then joining all the blacks together, and joining all the whites together, (and bonding all the grounds as well), should restore everything back to normal. Originally, the junction box would have had a line that provided power coming in, then power leaving the box and serving the garage plugs and the bathroom, along with the line that provided the switch leg.

As for not using the junction box for a fixture because it has 4 lines already, well, if you really want a light fixture, you could always get a larger junction box. There are several to choose from, the deeper they are, the more wires they will allow. All electrical boxes are measured for Cubic Inch capacity, and the Code will allow X# of wires in the box depending on its size. Many manufacturers state inside the box what the limitations are for specific wire sizes.

Regarding getting the garage sheetrocked, be sure to plan out all your electrical device needs before the walls are closed up. I cant tell you how many time people forgot to plan for something and had wished it was wired for before the walls were rocked!

Ok Theresa, you have a few things to consider and check into now, so let me know what you find out. Photos always help out, i'm anxious to find out id you discover a GFCI device. Snap a picture of your panel and the panel index if its convenient as I like to see how the circuits were planned for your home and how they may pertain to your project.

Be careful, and as always identify your power source and turn it off before working on the circuit. If you think your getting in over your head, then back off and call a professional electrician. Let me know if this helps or if you have anymore question ok I really enjoy getting the feed back!
Thanks very much, Dave.

Hello Dave,
Thanks for the information. It appears from the information you provided that I need to add a switch to these wires (there was a switch, but I removed it - big mistake on my part).

Since, I'm adding a switch, I will add a light fixture also (since that how the diagram shows it). I will work on this night. There is a GFCI in the garage. Believe it or not it was my blow drier that made me realize I had a problem.

I tried resetting the GFCI outlet and that did not work (this outlet is not longer getting power). I even tried replacing the GFCI that did solve the problem either. Am I correct that the main line (line with power) gets connected to the white wire from the switch And the remaining black lines (except for the switch) get connected to those.

The black line from the switch get connected to the light. And all the remaining white wires get connected together. I will send more pictures when I'm done with the project.
Thanks for your help- Theresa.


» You Can Avoid Costly Mistakes! «

Here is How to Do It:
Wire It Right with the help of my Illustrated Wiring Book

Great for any Home Wiring Project.


  electrical wiring  

Complete Guide to Home Electrical Wiring

Perfect for Homeowners, Students,
Handyman, Handywomen, and Electricians
Includes:
Wiring GFCI Outlets
Wiring Home Electric Circuits
120 Volt and 240 Volt Outlet Circuits
Wiring Light Switches
Wiring 3-Wire and 4-Wire Electric Range
Wiring 3-Wire and 4-Wire Dryer Cord and Dryer Outlet
How to Troubleshoot and Repair Electrical Wiring
Wiring Methods for Upgrading Electrical Wiring
NEC Codes for Home Electrical Wiring
....and much more.




Electrical Tips to Help You Wire it Right

The Safest Way to Test Electrical Devices and Identify Electric Wires!

The Non-Contact Electrical Tester
This is a testing tool that I have had in my personal electrical tool pouch for years, and is the first test tool I grab to help identify electrical wiring. It is a Non-contact tester that I use to easily Detect Voltage in Cables, Cords, Circuit Breakers, Lighting Fixtures, Switches, Outlets and Wires. Simply insert the end of the tester into an outlet, lamp socket, or hold the end of the tester against the wire you wish to test. Very handy and easy to use.

The Quickest Way to Check for Faulty Electrical Wiring!

The Plug-In Outlet Tester
This is the first tool I grab to troubleshoot a problem with outlet circuit wiring. This popular tester is also used by most inspectors to test for power and check the polarity of circuit wiring.
It detects probable improper wiring conditions in standard 110-125 VAC outlets Provides 6 probable wiring conditions that are quick and easy to read for ultimate efficiency Lights indicate if wiring is correct and indicator light chart is included Tests standard 3-wire outlets UL Listed Light indicates if wiring is incorrect Very handy and easy to use.

Strip Off Wire Insulation without Nicking and Damaging the Electric Wire!

The Wire Stripper and Wire Cutter
My absolute favorite wire stripping tool that I have had in my personal electrical tool pouch for years, and this is the tool I use to safely strip electrical wires.
This handy tool has multiple uses:
The wire gauges are shown on the side of the tool so you know which slot to use for stripping insulation.
The end of the tool can be used to grip and bend wire which is handy for attaching wire onto the screw terminals of switches and outlets..

The wire stripper will work on both solid and stranded wire. This tool is Very Handy and Easy to Use.





RELATED


More about Garage re project

How To Wire a Thermostat
How do I know which wires to connect to my new Thermostat Terminals? Typical Thermostat Wiring for HVAC Furnace Heating and Air Conditioning, Thermostat Wire Connections.

How to wire a range for 3-wire and 4-wire cords
I wired my 3 wire 40amp electric range and the electric burners turn on, but the control panel does not work. Wire and 4-Wire Cord Connections for an Electric Range or Freestanding Stove, Connecting the Ground Wire, and Installing a New Circuit for an Electric Range.

Electric Water Heater Wiring and Video
How to Connected the Wires to a Water Heater | Common Wiring Methods for wiring an Electric Water Heater, Basic Water Heater Circuit Requirements, Connect the Water Heater Wiring.

Installing a GFCI Outlet Without a Ground Wire Video
How Can I Install a GFCI outlet on a 2wire circuit that does not have a ground wire? How to Install a GFCI Outlet Where There is No Ground Wire.

Electrical Code for Garage GFI Outlets and Receptacles
How to Plan and Install Electrical Wiring for Garage Outlets and Lighting Circuits: Electrical Codes about GFCI protection for 15A and 20A, 125V receptacles in garages.

Timer Control for Outdoor Christmas Lights
How can outdoor holiday lights be wired on a grounded timer into a GFCI receptacle? How to Put Outdoor Christmas Lights on a Timer Switch.

How to Install an Electrical Sub Panel
Thinking about installing a Sub Panel? Here is what must be considered first, and you may find that you really do not need a sub panel at all.

Causes Of Electrical Shock in Homes
What causes a shock when touching a light switch or water facet, how can this be fixed? How Incorrect Electrical Wiring Can Produce Electric Shocks.

garage re project - 1686