Electrician Training Electrical Certification wiring recessed light fixtures Electrical Wiring Electrical Troubleshooting and Electrical Repairs wire outdoor light fixture Home Electrical Wiring Diagrams

wiring home generator and transfer switch wiring a 220 volt range cord outlet Wiring for GFCI Outlets Wiring Outlets and a Switched Outlet Wiring and Installing Ceiling Fans and Remote Controls wire dimmer switch wiring diagrams for switches wiring a dryer cord and 220 outlet circuit breaker panel
Electrical Wire and Cable
ask the electrician
Electrician Training Electrical Certification wiring recessed light fixtures Electrical Wiring Electrical Troubleshooting and Electrical Repairs wire outdoor light fixture Home Electrical Wiring Diagrams
wiring home generator and transfer switch wiring a 220 volt range cord outlet Wiring for GFCI Outlets Wiring Outlets and a Switched Outlet How to Installing and Wire Ceiling Fans and Remote Controls wire dimmer switch wiring diagrams for switches wiring a dryer cord and 220 outlet circuit breaker panel
Electrical Wire and Cable

Foreign voltage power converter


<< Save Energy With Lighting Controls Learn about Lighting for the Home >>
electrical power wiring Summary: Electrical power Question: I've got a challenge. Before I left the states, I purchased a Frigidaire stackable washer/dryer, model FEX831FS1 to be used in Jordan.


Electrical Troubleshooting: Foreign voltage power converter


Electrical Wiring Video

Install a Generator and Transfer Switch Panel

NOTE: A List of All my Helpful Videos

Will Display at the End of This Video

So Keep Watching So I Can Help You Wire it Right!


Check out my YouTube Channel:
» AskTheElectrician «
and Subscribe!


Electrical Power Question:
I've got a challenge. Before I left the states, I purchased a Frigidaire stackable washer/dryer, model FEX831FS1 to be used in Jordan. In the reading I've done I realize that going from 60 to 50 will result in: The motor turns 17% slower The internal current goes up by 17% The power (watt) goes down with 17 % The mechanical cooling is less, because of 17% less turns The result is a higher current, then designed by the manufacturer and the insulation of the electrical wiring deteriorate much quicker, which after sometime results in a burn-out. I know the unit is not intended to operate here, but returning

the unit would not be cost efficient, so I just need to get it to operate. Is there a way to get this unit to operate here in Jordan? Thank you, Todd S Mafraq, Jordan.

Hi Todd - Great Electrical Repair Question!
I looked over the Installation Guide which you attached and could not identify your specific unit,not a problem though - you need to tell me if your unit uses Gas or if it is all Electric. we have toestablish the specific Voltage and Load of the unit to try to find a converter.I believe Jordan is 230 Volt, 50 Hz as you mentioned and the 50 Hz will cause the motor to run warmerthan normal, not cooler.Here is a link to help identify which plug configuration you have for the unit: http://users.pandora.be/worldstandards/electricity.htm#plugs_cI just Googled your Model # and it looks like it is all electric. The concern is that it appears that the washer motorand Cycle Timer is 120 Volts - not good. If all the components were 230 Volt it would have better longevity,but only time will tell. You will also experience the timing of the wash and dry cycles to be off a little.Todd, all I will be able to do is to Google for a converter that would work for you. Outside of that you couldsee about swapping out the motors, but I think that would be more trouble and money that it is worth.Another idea is to find someone who is returning to the states and see if they could buy your unit. If youare in the military, they may be able to ship it for free or low cost (?).Identify the Plug Configuration from the link above and lets see what your will be plugging into.One thing for sure is that your unit will need a third prong to create the neutral for the 120 Volt devices.Let me know what you think - I'll do my best to find a converter for you. I know what your up against - I'veworked on projects in the Philippines and brazil and burnt up a lot of equipment from the states.Let me know - ok? From: Todd SDave, thanks for the timeliness of your reply.Yes, it is an electric unit. I believe it is the type C .I'm checking with a local friend here to see if any of the others can be used.I just looked back at my original email requesting the unit from the salesman and I made the mistake of requesting a 220v .I should have requested a 230v.On this unit for clarification, is the dryer 220 volt and the wash machine 110 volt .or are they both 220 volt.Correct me if I'm wrong on this, but with a 110 you have 2 phase wires and with a 220 you have 1 phase wire and 1 neutral. Can this only be hooked up one way over the other?I won't have the luxury of being able to sell it .I'll have to use it.Attached is the wiring diagram of the unit
Thanks, Todd Thank you so much for your help.ToddI believe you'll have problems using this unit with the type C plug.The reason is because the type C plug has no provision for a Ground or Neutral.The Ground and Neutral are bonded at the Main Service Panel, and this conductoris needed for the 110 Volt components of your unit, as mentioned before.If I read the attached schematic correctly, the only components using 220 Voltare the Heating Elements and the Dryer Motor, everything else is 110Volt.So what you actually have is a split system, but the majority of the control functionsare 110Volt.For clarification - 220 or 230 Volt used to be 2 lines (phases) of 110-115Volts and a Ground - a 3-wire system.Now because of the code changes all new units like this are a 4-wire system - its the same as the 3-wire, onlyrequiring a separate insulated Neutral.Yes there are still a lot of 3-wire units working just fine, as you see in the installation manual

In many casesthe Ground and Neutral become bonded internally in the unit, but I expect this will change soon with newer unitsand the 3-wire units will be obsolete.Also - the type C plug has limited amperage and may not provide the amperage your unit requires 30 amps at 240 voltswhich will actually be more because your voltage is lower.The lower the voltage the higher the amperage and this requires the correct wire size, otherwise you could overheat the wire.Find a local reliable electrician who can help you with this, that would be my suggestion. They would most likelyinstall a separate 3-wire circuit with the ground or neutral your unit requires.Tests must be taken to verify each power leg to ground and the 3rd conductor, but also verify the integrity of the ground path.Just be safe, and don't take a chance until you are sure the unit has what it requires,and the service is right and safe all around.I'll be hitting the hay for now - almost 3 a.m. but I will check email tomorrow.Best Wishes,Dave RongeyDave, thanks for the timeliness of your reply.Yes, it is an electric unit. I believe it is the type C .I'm checking with a local friend here to see if any of the others can be used.I just looked back at my original email requesting the unit from the salesman and I made the mistake of requesting a 220v .I should have requested a 230v.On this unit for clarification, is the dryer 220 volt and the wash machine 110 volt .or are they both 220 volt.Correct me if I'm wrong on this, but with a 110 you have 2 phase wires and with a 220 you have 1 phase wire and 1 neutral. Can this only be hooked up one way over the other?I won't have the luxury of being able to sell it .I'll have to use it.Attached is the wiring diagram of the unit
Thanks, ToddI looked over the Installation Guide which you attached and could not identify your specific unit,not a problem though - you need to tell me if your unit uses Gas or if it is all Electric. we have toestablish the specific Voltage and Load of the unit to try to find a converter.I believe Jordan is 230 Volt, 50 Hz as you mentioned and the 50 Hz will cause the motor to run warmerthan normal, not cooler.Here is a link to help identify which plug configuration you have for the unit: http://users.pandora.be/worldstandards/electricity.htm#plugs_cI just Googled your Model # and it looks like it is all electric. The concern is that it appears that the washer motorand Cycle Timer is 120 Volts - not good. If all the components were 230 Volt it would have better longevity,but only time will tell. You will also experience the timing of the wash and dry cycles to be off a little.Todd, all I will be able to do is to Google for a converter that would work for you. Outside of that you couldsee about swapping out the motors, but I think that would be more trouble and money that it is worth.Another idea is to find someone who is returning to the states and see if they could buy your unit. If youare in the military, they may be able to ship it for free or low cost (?).Identify the Plug Configuration from the link above and lets see what your will be plugging into.One thing for sure is that your unit will need a third prong to create the neutral for the 120 Volt devices.Let me know what you think - I'll do my best to find a converter for you. I know what your up against - I'veworked on projects in the Philippines and brazil and burnt up a lot of equipment from the states.Let me know - ok?
Dave Rongey

 

» You Can Avoid Costly Mistakes! «

Here is How to Do It:
Wire It Right with the help of my Illustrated Wiring Book

Great for any Home Wiring Project.


  electrical wiring  

Complete Guide to Home Electrical Wiring

Perfect for Homeowners, Students,
Handyman, Handywomen, and Electricians
Includes:
Wiring GFCI Outlets
Wiring Home Electric Circuits
120 Volt and 240 Volt Outlet Circuits
Wiring Light Switches
Wiring 3-Wire and 4-Wire Electric Range
Wiring 3-Wire and 4-Wire Dryer Cord and Dryer Outlet
How to Troubleshoot and Repair Electrical Wiring
Wiring Methods for Upgrading Electrical Wiring
NEC Codes for Home Electrical Wiring
....and much more.




Electrical Tips to Help You Wire it Right

The Safest Way to Test Electrical Devices and Identify Electric Wires!

The Non-Contact Electrical Tester
This is a testing tool that I have had in my personal electrical tool pouch for years, and is the first test tool I grab to help identify electrical wiring. It is a Non-contact tester that I use to easily Detect Voltage in Cables, Cords, Circuit Breakers, Lighting Fixtures, Switches, Outlets and Wires. Simply insert the end of the tester into an outlet, lamp socket, or hold the end of the tester against the wire you wish to test. Very handy and easy to use.

The Quickest Way to Check for Faulty Electrical Wiring!

The Plug-In Outlet Tester
This is the first tool I grab to troubleshoot a problem with outlet circuit wiring. This popular tester is also used by most inspectors to test for power and check the polarity of circuit wiring.
It detects probable improper wiring conditions in standard 110-125 VAC outlets Provides 6 probable wiring conditions that are quick and easy to read for ultimate efficiency Lights indicate if wiring is correct and indicator light chart is included Tests standard 3-wire outlets UL Listed Light indicates if wiring is incorrect Very handy and easy to use.

Strip Off Wire Insulation without Nicking and Damaging the Electric Wire!

The Wire Stripper and Wire Cutter
My absolute favorite wire stripping tool that I have had in my personal electrical tool pouch for years, and this is the tool I use to safely strip electrical wires.
This handy tool has multiple uses:
The wire gauges are shown on the side of the tool so you know which slot to use for stripping insulation.
The end of the tool can be used to grip and bend wire which is handy for attaching wire onto the screw terminals of switches and outlets..

The wire stripper will work on both solid and stranded wire. This tool is Very Handy and Easy to Use.

electrical parts

Residential Electrical Parts and Accessories


Light Switches

120volt Outlets

Circuit Breakers

Electrician Tools

Voltage Testers





RELATED


More about Foreign voltage power converter

Sitemap
Ceiling Fans Airplane Ceiling Fan Airplane Ceiling Fan Ceiling Fan Direction Summer Ceiling Fan Direction Winter Ceiling Fan Wiring Diagram 1 Ceiling Fan Wiring Diagram 2 Ceiling Fan Wiring Questions and Answers Ceiling Fans Wiring – Part 1 Ceiling Fans Wiring – Part 2 Introduction to Ceiling Fan Remote Controls Outdoor Ceiling Fan 1 Outdoor […]

Using Electrical Appliances in Foreign Countries
Taking Domestic Electrical Equipment to a Foreign Country: The safest way to know if your electrical appliance will be safe to connect and use with a foreign electrical system.

foreign voltage power converter - 597