Articles about Grounding

Installing an Electrical Circuit for a Whirlpool Tub


How to Install an Electrical Circuit for a Whirlpool Tub: Where a 240 volt circuit is required with a neutral a 3-wire cable with a ground must be installed, 4 wires in all.


Category:


Grounding Method For Sub-Panel Circuit


Does the receptacle ground connect to the isolated ground or to the neutral in the sub-panel…


Category:


Electrical Code for Wire Type and Size


How to Know What Wire Size and Type to use for Home Electrical Wiring – Continuing the circuit with the same wire size and type is essential to maintain the integrity of the circuit.


Category:


Essential Electrical Grounding for Pools, Spas and Hot Tubs


What is the right way to Ground Pools, Spas and Hot Tubs? I am installing a packaged above-ground spa. I have a 50amp breaker in my panel feeding a GFI disconnect panel near the spa.


Category:


Considerations When Grounding Electrical Equipment


I am trying to ground some equipment in an electrical room. I have found a small surge protector that has an external grounding lug that I am using as my primary grounding point.


Category:


How To Ground Old Two-Wire Outlets


Can I run a line from the panel to one location then bring all of the grounds from the outlets on one circuit to that location and tie them all together there, or do I have to run the ground to each outlet and splice each one in there? Attaching a Ground Wire For Old 2Wire Outlets: Electrical Grounding Methods and Requirements.


Category:


Testing An Electrical Circuit For A Ground


Should I make sure my Circuits are Properly Grounded? How to Determine if a Circuit is Actually Grounded and how to proceed to bond your system for equipment protection


Category:


Hot Tub Circuit Ground Wire


Does a Hot Tub require a separate ground wire from the main panel? How to Bond the Ground Wire for a Hot Tub Circuit, Connection to the Ground Terminal, Separate Neutral and Ground Wires, Hot Tube Circuit Cable Size.


Category:


Electrical Question about Reducing the Value of Ze


The Correct Method to be used When Testing an Electrical Installation for Earth Loop Impedance: Accurately Measuring the Value of Zs at a Remote End of a Circuit.


Category:


Grounding an Electrical Equipment Disconnect Switch


How to Bond The Ground: I Need to Place A Disconnect Between A Radial Saw And The Main Power Breaker.


Category:


Electrical Conduit and Ground Wires


Methods for Grounding Metallic Electrical Conduits – In some installations there will be bonding devices that will be required for proper bonding. So as long as these measures are in place then this should not have an effect on the performance of the GFCI outlet.


Category:


Sub Panel Grounding and Neutrals


Understanding Grounding for Sub Panels: When you add a second electrical panel with separate neutral and common bars, do you ground the common to the box along with a ground rod connection?


Category:


PVC Water Pipes Not For Grounding


The Importance of a Bonded Ground System: Is it possible to use an outside spigot to ground a satellite dish when the underlying plumbing in our new house is PVC?


Category:


Electrical Code for New Construction and Ground Rods


New Construction and Ground Rods: What is the current code for ground rods on new construction?


Category:


Electrical Safety and Stray Voltage


Tonight while attempting to draw water in the tub we felt electrical sensations while the water was running in the tub…


Category:


Electric Outlet Ground Testing


It seems that all of my outlets on the second floor do not have a ground. I have a “smart” power strips that show “no ground” and the bathroom GCFI is tripped…


Category: